logo
products
PRODUCTS DETAILS
Home > Products >
LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime

LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime

MOQ: 1
Price: 694$/piece
Standard Packaging: 103 x 45 x 46mm
Delivery Period: 3 day
Payment Method: T/T
Supply Capacity: 1piece in stock
Detail Information
Place of Origin
GERMANY
Brand Name
IFM
Certification
3C
Model Number
LDL100
System:
Gold-plated Contacts
Communication Interface:
IO-Link
Weight[g]:
270.5
Highlight:

LDL100 Conductive conductivity sensor

,

High quality Conductive conductivity sensor

,

Compact Conductive conductivity sensor

Product Description
Product characteristics
Number of inputs and outputs Number of analog outputs: 1
Process connection G 1/2 external thread
Application
System gold-plated contacts
Media   Conductive liquids
Note on media   water
  milk
  CIP liquids
Cannot be used for   See the operating instructions, chapter "Function and features".
Medium temperature [°C]   -25...100; (< 1 h: 150)
Pressure rating [bar]   16
Vacuum resistance [mbar]   -1000
Electrical data
Operating voltage [V]   18...30 DC
Current consumption [mA]   < 60
Protection class   III
Reverse polarity protection   yes
Power-on delay time [s]   2
Inputs / outputs
Number of inputs and outputs Number of analog outputs: 1
Outputs
Total number of outputs 1
Output signal analog signal; IO-Link
Output function   analog output; scalable; selectable conductivity / temperature
Number of analog outputs     1
Analog current output [mA]   4...20
Max. load [Ω]   500
LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime 0ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 —
 
LDL100
Conductive conductivity sensor
COND CONDUCTIVITY HYG G1/2
Measuring/setting range
Measuring range [µS/cm]   100...15000  
Temperature measurement
Measuring range [°C]   -25...150  
Accuracy / deviations
Accuracy (in the measuring 10 % MW ± 25 µS/cm  
range)  
Conductivity measurement
Resolution [µS/cm]   1
Drift [%/K]   0,2 %/K MW ± 25 µS/cm
Repeatability     5 % MW ± 25 µS/cm
Long-term stability   1 % MW ± 25 µS/cm
Temperature measurement
Accuracy [K]   20...50 °C: < ± 0,5 K;
-25...150 °C: < ± 1,5 K
Repeatability [K]   2
Resolution [K]   0.1
Reaction times
Conductivity measurement
Response time [s] < 2; (T09; Damping = 0)  
Temperature measurement
Response time [s] < 9; (T09)  
Interfaces
Communication interface IO-Link  
Transmission type COM2 (38,4 kBaud)  
IO-Link revision 1.1  
SDCI standard IEC 61131-9  
IO-Link device ID 0x000399 / 921  
Profiles   Measuring Sensor, Identification and Diagnosis
SIO mode   no
Required master port class   A
Process data analogue   1
Min. process cycle time [ms] 5.6
Operating conditions
Ambient temperature [°C] -40...60  
Storage temperature [°C] -40...85
Protection IP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar)
Tests / approvals
EMC   DIN EN 61000-6-2  
  DIN EN 61000-6-3  
Shock resistance   DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance   DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years]   172
LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime 1 ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 —
 
LDL100
Conductive conductivity sensor
COND CONDUCTIVITY HYG G1/2
Mechanical data
Weight [g] 270.5  
Material stainless steel (1.4404 / 316L); PEEK; PEI; FKM  
Materials (wetted parts) PEEK; stainless steel (1.4404 / 316L)
Process connection G 1/2 external thread
Remarks
Remarks   MW = Measured value
Pack quantity   1 pcs.
Electrical connection
products
PRODUCTS DETAILS
LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime
MOQ: 1
Price: 694$/piece
Standard Packaging: 103 x 45 x 46mm
Delivery Period: 3 day
Payment Method: T/T
Supply Capacity: 1piece in stock
Detail Information
Place of Origin
GERMANY
Brand Name
IFM
Certification
3C
Model Number
LDL100
System:
Gold-plated Contacts
Communication Interface:
IO-Link
Weight[g]:
270.5
Minimum Order Quantity:
1
Price:
694$/piece
Packaging Details:
103 x 45 x 46mm
Delivery Time:
3 day
Payment Terms:
T/T
Supply Ability:
1piece in stock
Highlight

LDL100 Conductive conductivity sensor

,

High quality Conductive conductivity sensor

,

Compact Conductive conductivity sensor

Product Description
Product characteristics
Number of inputs and outputs Number of analog outputs: 1
Process connection G 1/2 external thread
Application
System gold-plated contacts
Media   Conductive liquids
Note on media   water
  milk
  CIP liquids
Cannot be used for   See the operating instructions, chapter "Function and features".
Medium temperature [°C]   -25...100; (< 1 h: 150)
Pressure rating [bar]   16
Vacuum resistance [mbar]   -1000
Electrical data
Operating voltage [V]   18...30 DC
Current consumption [mA]   < 60
Protection class   III
Reverse polarity protection   yes
Power-on delay time [s]   2
Inputs / outputs
Number of inputs and outputs Number of analog outputs: 1
Outputs
Total number of outputs 1
Output signal analog signal; IO-Link
Output function   analog output; scalable; selectable conductivity / temperature
Number of analog outputs     1
Analog current output [mA]   4...20
Max. load [Ω]   500
LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime 0ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 —
 
LDL100
Conductive conductivity sensor
COND CONDUCTIVITY HYG G1/2
Measuring/setting range
Measuring range [µS/cm]   100...15000  
Temperature measurement
Measuring range [°C]   -25...150  
Accuracy / deviations
Accuracy (in the measuring 10 % MW ± 25 µS/cm  
range)  
Conductivity measurement
Resolution [µS/cm]   1
Drift [%/K]   0,2 %/K MW ± 25 µS/cm
Repeatability     5 % MW ± 25 µS/cm
Long-term stability   1 % MW ± 25 µS/cm
Temperature measurement
Accuracy [K]   20...50 °C: < ± 0,5 K;
-25...150 °C: < ± 1,5 K
Repeatability [K]   2
Resolution [K]   0.1
Reaction times
Conductivity measurement
Response time [s] < 2; (T09; Damping = 0)  
Temperature measurement
Response time [s] < 9; (T09)  
Interfaces
Communication interface IO-Link  
Transmission type COM2 (38,4 kBaud)  
IO-Link revision 1.1  
SDCI standard IEC 61131-9  
IO-Link device ID 0x000399 / 921  
Profiles   Measuring Sensor, Identification and Diagnosis
SIO mode   no
Required master port class   A
Process data analogue   1
Min. process cycle time [ms] 5.6
Operating conditions
Ambient temperature [°C] -40...60  
Storage temperature [°C] -40...85
Protection IP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar)
Tests / approvals
EMC   DIN EN 61000-6-2  
  DIN EN 61000-6-3  
Shock resistance   DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance   DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years]   172
LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime 1 ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 —
 
LDL100
Conductive conductivity sensor
COND CONDUCTIVITY HYG G1/2
Mechanical data
Weight [g] 270.5  
Material stainless steel (1.4404 / 316L); PEEK; PEI; FKM  
Materials (wetted parts) PEEK; stainless steel (1.4404 / 316L)
Process connection G 1/2 external thread
Remarks
Remarks   MW = Measured value
Pack quantity   1 pcs.
Electrical connection