logo
products
PRODUCTS DETAILS
Home > Products >
PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents

PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents

MOQ: 1
Price: 743$/piece
Standard Packaging: 103 x 45 x 46mm
Delivery Period: 3 day
Payment Method: T/T
Supply Capacity: 1piece in stock
Detail Information
Place of Origin
GERMANY
Brand Name
IFM
Certification
3C
Model Number
PI1709
System:
Gold-plated Contacts
Weight[g]:
306.9
Dimensions[mm]:
Ø 30.2 / L = 111
Connection:
Connector: 1 X M12; Coding: A; Contacts: Gold-plated
Product Description
Product characteristics
Number of inputs and outputs   Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range   PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 0 PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 1 PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 2 PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 3-1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa
Process connection   threaded connection G 1 external thread Aseptoflex Vario
Application
Special feature   Gold-plated contacts
Measuring element   ceramic-capacitive pressure measuring cell
Temperature monitoring   no
Application   flush mountable for the food and beverage industry
Media   viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]     -25...150
Min. bursting pressure   30000 mbar 435 psi 3000 kPa
Pressure rating   10000 mbar 145 psi 1000 kPa
Vacuum resistance [mbar]     -1000
Type of pressure     relative pressure; vacuum
No dead space   yes
MAWP (for applications
according to CRN)
[bar]   10
Electrical data
Operating voltage [V]   18...30 DC
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 4ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
 
PM1709
Flush pressure sensor
PM-1-1BREA01-E-ZVG/US
Min. insulation resistance [MΩ]   100; (500 V DC)  
Protection class   III
Reverse polarity protection   yes
Integrated watchdog   yes
2-wire
Current consumption [mA]   3.5...21.5  
Power-on delay time [s]   1
3-wire
Current consumption [mA]   < 45  
Power-on delay time [s]   0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs   2  
Output signal   analogue signal; IO-Link; (configurable)  
Number of digital outputs     1; (IO-Link)    
Number of analogue outputs   1
Analogue current output [mA]   4...20; (scalable)
Max. load [Ω]   700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proof   yes
Overload protection   yes
Measuring/setting range
Measuring range   -1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa
Analogue start point   -1000...600 mbar -14.5...8.7 psi -100...60 kPa
Analogue endpoint   -600...1000 mbar -8.7...14.5 psi -60...100 kPa
Insteps of   1 mbar 0.01 psi 0.1 kPa
Factory setting     ASP = -1000 mbar AEP = 1000 mbar
Accuracy / deviations
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation
[% of the span]
  < ± 0,2; (linearity incl. hysteresis and repeatability,
limit value setting to DIN EN IEC 62828-1)
Linearity deviation [% of the span]   < ± 0,15; (Turn down 1:1)
Hysteresis deviation   < ± 0,15; (Turn down 1:1)
  [% of the span]  
       
Long-term stability
[% of the span]
  < ± 0,1; (Turn down 1:1; per year)
Total deviation over
temperature range
  Temperature range total deviation
  -25...15 °C Characteristics deviation ± 0,05 % of the
span / 10 K
  15...80 °C Characteristics deviation
  80...150 °C Characteristics deviation ± 0,1 % of the span /
10 K
Notes on the accuracy /
deviation
  for further details see section Diagrams and graphs
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 5 ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
 
PM1709
Flush pressure sensor
PM-1-1BREA01-E-ZVG/US
Response times
Damping for the analogue [s] 0...4  
output dAA  
2-wire
Step response time analogue [ms] 30  
output  
3-wire
Step response time analogue [ms] 7  
output  
Interfaces
Communication interface   IO-Link  
Transmission type   COM2 (38,4 kBaud)  
IO-Link revision   1.1  
SDCI standard   IEC 61131-9  
Profiles   Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
SIO mode   no
Required master port type   A
Process data analogue   3
Min. process cycle time [ms]   3.2
IO-Link resolution pressure [mbar]   0.5
IO-Link functions (acyclical)     application specific tag; internal temperature  
Supported DeviceIDs   Type of operation DeviceID
  default 667
Operating conditions
Ambient temperature [°C] -25...80  
Storage temperature [°C]   -40...100  
Protection   IP 67; IP 68; IP 69K
Tests / approvals
EMC   DIN EN 61000-6-2  
  DIN EN 61000-6-3  
Shock resistance   DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance   DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years]     323  
Note on approval   factory certificate available as download at www.factory-certificate.ifm
UL approval   UL Approval no. J021
Mechanical data
Weight [g]   306.9  
Housing     cylindrical  
Dimensions [mm]   Ø 30.2 / L = 111  
Materials     stainless steel (316L/1.4404); PBT
Materials (wetted parts)     ceramics (99.9 % Al2O3); stainless steel (316L/1.4435);
surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles     100 million
Tightening torque [Nm]     35  
Process connection   threaded connection G 1 external thread Aseptoflex Vario
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 6ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
 
PM1709
Flush pressure sensor
PM-1-1BREA01-E-ZVG/US
Remarks
Pack quantity 1 pcs.  
Electrical connection
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 7Connector: 1 x M12; coding: A; Contacts: gold-plated
Connection
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 8
1 connection for 2-wire operation ( analogue )
2 connection for 3-wire operation ( analogue / IO-Link )
OUT1 : IO-Link
OUT2 : analogue output
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 9ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
 
PM1709
Flush pressure sensor
PM-1-1BREA01-E-ZVG/US
Diagrams and graphs
ambient temperature influence on PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 10X temperature
Y total deviation
the accuracy
products
PRODUCTS DETAILS
PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents
MOQ: 1
Price: 743$/piece
Standard Packaging: 103 x 45 x 46mm
Delivery Period: 3 day
Payment Method: T/T
Supply Capacity: 1piece in stock
Detail Information
Place of Origin
GERMANY
Brand Name
IFM
Certification
3C
Model Number
PI1709
System:
Gold-plated Contacts
Weight[g]:
306.9
Dimensions[mm]:
Ø 30.2 / L = 111
Connection:
Connector: 1 X M12; Coding: A; Contacts: Gold-plated
Minimum Order Quantity:
1
Price:
743$/piece
Packaging Details:
103 x 45 x 46mm
Delivery Time:
3 day
Payment Terms:
T/T
Supply Ability:
1piece in stock
Product Description
Product characteristics
Number of inputs and outputs   Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range   PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 0 PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 1 PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 2 PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 3-1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa
Process connection   threaded connection G 1 external thread Aseptoflex Vario
Application
Special feature   Gold-plated contacts
Measuring element   ceramic-capacitive pressure measuring cell
Temperature monitoring   no
Application   flush mountable for the food and beverage industry
Media   viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]     -25...150
Min. bursting pressure   30000 mbar 435 psi 3000 kPa
Pressure rating   10000 mbar 145 psi 1000 kPa
Vacuum resistance [mbar]     -1000
Type of pressure     relative pressure; vacuum
No dead space   yes
MAWP (for applications
according to CRN)
[bar]   10
Electrical data
Operating voltage [V]   18...30 DC
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 4ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
 
PM1709
Flush pressure sensor
PM-1-1BREA01-E-ZVG/US
Min. insulation resistance [MΩ]   100; (500 V DC)  
Protection class   III
Reverse polarity protection   yes
Integrated watchdog   yes
2-wire
Current consumption [mA]   3.5...21.5  
Power-on delay time [s]   1
3-wire
Current consumption [mA]   < 45  
Power-on delay time [s]   0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1; Number of analogue outputs: 1
Outputs
Total number of outputs   2  
Output signal   analogue signal; IO-Link; (configurable)  
Number of digital outputs     1; (IO-Link)    
Number of analogue outputs   1
Analogue current output [mA]   4...20; (scalable)
Max. load [Ω]   700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proof   yes
Overload protection   yes
Measuring/setting range
Measuring range   -1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa
Analogue start point   -1000...600 mbar -14.5...8.7 psi -100...60 kPa
Analogue endpoint   -600...1000 mbar -8.7...14.5 psi -60...100 kPa
Insteps of   1 mbar 0.01 psi 0.1 kPa
Factory setting     ASP = -1000 mbar AEP = 1000 mbar
Accuracy / deviations
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation
[% of the span]
  < ± 0,2; (linearity incl. hysteresis and repeatability,
limit value setting to DIN EN IEC 62828-1)
Linearity deviation [% of the span]   < ± 0,15; (Turn down 1:1)
Hysteresis deviation   < ± 0,15; (Turn down 1:1)
  [% of the span]  
       
Long-term stability
[% of the span]
  < ± 0,1; (Turn down 1:1; per year)
Total deviation over
temperature range
  Temperature range total deviation
  -25...15 °C Characteristics deviation ± 0,05 % of the
span / 10 K
  15...80 °C Characteristics deviation
  80...150 °C Characteristics deviation ± 0,1 % of the span /
10 K
Notes on the accuracy /
deviation
  for further details see section Diagrams and graphs
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 5 ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
 
PM1709
Flush pressure sensor
PM-1-1BREA01-E-ZVG/US
Response times
Damping for the analogue [s] 0...4  
output dAA  
2-wire
Step response time analogue [ms] 30  
output  
3-wire
Step response time analogue [ms] 7  
output  
Interfaces
Communication interface   IO-Link  
Transmission type   COM2 (38,4 kBaud)  
IO-Link revision   1.1  
SDCI standard   IEC 61131-9  
Profiles   Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
SIO mode   no
Required master port type   A
Process data analogue   3
Min. process cycle time [ms]   3.2
IO-Link resolution pressure [mbar]   0.5
IO-Link functions (acyclical)     application specific tag; internal temperature  
Supported DeviceIDs   Type of operation DeviceID
  default 667
Operating conditions
Ambient temperature [°C] -25...80  
Storage temperature [°C]   -40...100  
Protection   IP 67; IP 68; IP 69K
Tests / approvals
EMC   DIN EN 61000-6-2  
  DIN EN 61000-6-3  
Shock resistance   DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance   DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years]     323  
Note on approval   factory certificate available as download at www.factory-certificate.ifm
UL approval   UL Approval no. J021
Mechanical data
Weight [g]   306.9  
Housing     cylindrical  
Dimensions [mm]   Ø 30.2 / L = 111  
Materials     stainless steel (316L/1.4404); PBT
Materials (wetted parts)     ceramics (99.9 % Al2O3); stainless steel (316L/1.4435);
surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles     100 million
Tightening torque [Nm]     35  
Process connection   threaded connection G 1 external thread Aseptoflex Vario
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 6ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
 
PM1709
Flush pressure sensor
PM-1-1BREA01-E-ZVG/US
Remarks
Pack quantity 1 pcs.  
Electrical connection
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 7Connector: 1 x M12; coding: A; Contacts: gold-plated
Connection
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 8
1 connection for 2-wire operation ( analogue )
2 connection for 3-wire operation ( analogue / IO-Link )
OUT1 : IO-Link
OUT2 : analogue output
PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 9ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
 
PM1709
Flush pressure sensor
PM-1-1BREA01-E-ZVG/US
Diagrams and graphs
ambient temperature influence on PI1709 - Flush pressure sensor with display - ifm - ifm electronic  Resistant to high-pressure cleaning with aggressive cleaning agents 10X temperature
Y total deviation
the accuracy