MOQ: | 1 |
Price: | $125/piece |
Standard Packaging: | 70*40*40mm |
Delivery Period: | 3 day |
Payment Method: | T/T |
Supply Capacity: | 1piece in stock |
Product characteristics | ||||||||||
Electrical design | PNP | |||||||||
Output function | normally open | |||||||||
Sensing range [mm] 8 Housing threaded type |
||||||||||
Dimensions [mm] | M18 x 1 / L = 46 | |||||||||
Application | ||||||||||
Special feature | Gold-plated contacts; Increased sensing range | |||||||||
Application | regular cleaning processes | |||||||||
Electrical data | ||||||||||
Operating voltage [V] | 10...36 DC | |||||||||
Current consumption [mA] 10; (24 V) Protection class II |
||||||||||
Reverse polarity protection | yes | |||||||||
Outputs | ||||||||||
Electrical design | PNP | |||||||||
Output function | normally open | |||||||||
Max. voltage drop switching output DC |
[V] | 2.5 | ||||||||
Permanent current rating of switching output DC |
[mA] | 100 | ||||||||
Switching frequency DC | [Hz] | 600 | ||||||||
Short-circuit protection | yes | |||||||||
Type of short-circuit protection |
pulsed | |||||||||
Overload | protection | yes | ||||||||
Detection zone | ||||||||||
Sensing range [mm] | 8 | |||||||||
Operating distance [mm] 0...6.48 Increased sensing range yes |
||||||||||
![]() |
||||||||||
IGT203 | ||||||||||
Inductive sensor | ||||||||||
IGB3008BBPKG/M/V4A/US-104-DPS | ||||||||||
Accuracy / deviations | ||||||||||
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 Hysteresis [% of Sr] 1...20 |
||||||||||
Operating conditions | ||||||||||
Ambient temperature [°C] 0...100 Protection IP 68; IP 69K; ("COP") |
||||||||||
Tests / approvals | ||||||||||
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | ||||||||
EN 61000-4-3 HF radiated | 10 V/m | |||||||||
EN 61000-4-4 Burst | 2 kV | |||||||||
EN 61000-4-6 HF conducted | 10 V | |||||||||
EN 55011 | class B | |||||||||
MTTF | [years] | 1727 | ||||||||
UL approval | Ta | 0...40 °C | ||||||||
Enclosure type | Type 1 | |||||||||
voltage supply | Limited Voltage/Current | |||||||||
File number UL | E174191 | |||||||||
Mechanical data | ||||||||||
Weight | [g] | 44.7 | ||||||||
Housing | threaded type | |||||||||
Mounting | flush mountable | |||||||||
Dimensions [mm] | M18 x 1 / L = 46 | |||||||||
Thread designation | M18 x 1 |
MOQ: | 1 |
Price: | $125/piece |
Standard Packaging: | 70*40*40mm |
Delivery Period: | 3 day |
Payment Method: | T/T |
Supply Capacity: | 1piece in stock |
Product characteristics | ||||||||||
Electrical design | PNP | |||||||||
Output function | normally open | |||||||||
Sensing range [mm] 8 Housing threaded type |
||||||||||
Dimensions [mm] | M18 x 1 / L = 46 | |||||||||
Application | ||||||||||
Special feature | Gold-plated contacts; Increased sensing range | |||||||||
Application | regular cleaning processes | |||||||||
Electrical data | ||||||||||
Operating voltage [V] | 10...36 DC | |||||||||
Current consumption [mA] 10; (24 V) Protection class II |
||||||||||
Reverse polarity protection | yes | |||||||||
Outputs | ||||||||||
Electrical design | PNP | |||||||||
Output function | normally open | |||||||||
Max. voltage drop switching output DC |
[V] | 2.5 | ||||||||
Permanent current rating of switching output DC |
[mA] | 100 | ||||||||
Switching frequency DC | [Hz] | 600 | ||||||||
Short-circuit protection | yes | |||||||||
Type of short-circuit protection |
pulsed | |||||||||
Overload | protection | yes | ||||||||
Detection zone | ||||||||||
Sensing range [mm] | 8 | |||||||||
Operating distance [mm] 0...6.48 Increased sensing range yes |
||||||||||
![]() |
||||||||||
IGT203 | ||||||||||
Inductive sensor | ||||||||||
IGB3008BBPKG/M/V4A/US-104-DPS | ||||||||||
Accuracy / deviations | ||||||||||
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 Hysteresis [% of Sr] 1...20 |
||||||||||
Operating conditions | ||||||||||
Ambient temperature [°C] 0...100 Protection IP 68; IP 69K; ("COP") |
||||||||||
Tests / approvals | ||||||||||
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | ||||||||
EN 61000-4-3 HF radiated | 10 V/m | |||||||||
EN 61000-4-4 Burst | 2 kV | |||||||||
EN 61000-4-6 HF conducted | 10 V | |||||||||
EN 55011 | class B | |||||||||
MTTF | [years] | 1727 | ||||||||
UL approval | Ta | 0...40 °C | ||||||||
Enclosure type | Type 1 | |||||||||
voltage supply | Limited Voltage/Current | |||||||||
File number UL | E174191 | |||||||||
Mechanical data | ||||||||||
Weight | [g] | 44.7 | ||||||||
Housing | threaded type | |||||||||
Mounting | flush mountable | |||||||||
Dimensions [mm] | M18 x 1 / L = 46 | |||||||||
Thread designation | M18 x 1 |