Product Identification and Basics
The X20DO9322, distinguished by its material number, is a digital output module by B&R. It serves as a key component in industrial control systems. With 12 digital outputs, it provides a significant capacity for driving various external devices. This module is designed to be an integral part of systems where digital signals need to be converted into physical actions, making it suitable for a wide range of industrial applications.
Technical Features
One of the main features of the X20DO9322 is its source connection design. The outputs are configured for a source circuit, which determines the direction of current flow. This design choice offers flexibility in circuit design and compatibility with different types of loads. It also features 1 - wire connections, simplifying the wiring process and reducing the complexity of installations. Additionally, the module comes with integrated output protection. This protection mechanism safeguards the module and connected devices from potential electrical faults such as short - circuits and over - currents.
Application - Oriented Advantages
In industrial settings, the X20DO9322 proves highly beneficial. Its 12 - output configuration allows for the control of multiple devices simultaneously, such as solenoid valves, relays, or indicator lights. The source connection design enables efficient power distribution to the connected loads. The integrated output protection enhances the reliability of the system, reducing the risk of equipment damage due to electrical malfunctions. The simplicity of the 1 - wire connections makes installation and maintenance easier, ultimately improving the overall efficiency of industrial operations.
Category
|
Details
|
General Information
|
|
- Material Number
|
X20DO9322
|
- Brand
|
B&R
|
- Product Type
|
Digital Output Module
|
- Function
|
Convert digital signals from control systems to drive external devices in industrial applications
|
- B&R ID Code
|
0x1B9A
|
- Warranty
|
Usually 12 months (varies by region and distributor)
|
Output Specifications
|
|
- Number of Outputs
|
12
|
- Output Signal Type
|
Digital
|
- Nominal Voltage
|
24 VDC
|
- Switching Voltage
|
24 VDC (-15% / +20%)
|
- Nominal Output Current
|
0.5 A
|
- Total Nominal Current
|
6 A
|
- Connection Type
|
1 - wire connections
|
- Output Circuit
|
Source
|
- Output Protection
|
Thermal shutdown in case of overcurrent or short - circuit; internal freewheeling diode for switching inductive loads
|
- Diagnostic Status
|
Output monitoring with 10 ms delay
|
- Leakage Current (Output Off)
|
5 µA
|
- Rds(on)
|
210 mΩ
|
- Peak Short - Circuit Current
|
< 12 A
|
- Overload/Short - Circuit Recovery Time
|
Approx. 10 ms (depends on module temperature)
|
- Switching Delay (0 → 1)
|
< 300 µs
|
- Switching Delay (1 → 0)
|
< 300 µs
|
- Switching Frequency (Resistive Load)
|
Max. 500 Hz
|
- Braking Voltage (Inductive Load)
|
Typ. 50 VDC
|
- Insulation Voltage (Channel - Bus)
|
500 Veff
|
Power Requirements
|
|
- Bus Power Consumption
|
0.26 W
|
- Internal I/O Power Consumption
|
1.15 W
|
- Additional Power Dissipation by Actuators (Resistive)
|
+0.63 W
|
Electrical Isolation
|
|
- Channel - Bus Isolation
|
Yes
|
- Channel - Channel Isolation
|
No
|
- Channel - I/O Power Supply Isolation
|
No
|
Status and Diagnostics
|
|
- Status Indicators
|
I/O function per channel, operating state, module status
|
- Diagnostics
|
Module run/error and output diagnostics available via LED status indicators and software
|
Environmental Conditions
|
|
- Operating Temperature (Horizontal Mounting)
|
- 25 °C to 60 °C
|
- Operating Temperature (Vertical Mounting)
|
- 25 °C to 50 °C
|
- Storage Temperature
|
- 40 °C to 85 °C
|
- Transportation Temperature
|
- 40 °C to 85 °C
|
- Relative Humidity (Operation)
|
5% - 95%, non - condensing
|
- Relative Humidity (Storage)
|
5% - 95%, non - condensing
|
- Relative Humidity (Transportation)
|
5% - 95%, non - condensing
|
- Mounting Orientation
|
Horizontal and vertical
|
- Installation Elevation
|
0 - 2000 m: no limitation; > 2000 m: ambient temperature reduction of 0.5 °C per 100 m
|
- Protection Class
|
IP20
|
Mechanical Properties
|
|
- Mounting Method
|
Likely plug - in mounting (details may refer to product manual)
|
- Dimensions (W x H x D)
|
Approximately 2.2 cm x 12.4 cm x 12.6 cm
|
- Weight
|
Approximately 0.1 kg
|
- Pitch
|
12.5 + 0.2 mm
|
- Mandatory Accessories
|
Bus modules (e.g., X20BM11, X20BM15); Terminal blocks (e.g., X20TB12)
|
Certifications
|
|
- CE
|
Yes
|
- UKCA
|
Yes
|
- ATEX
|
Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
|
- UL
|
cULus E115267 (industrial control equipment)
|
- HazLoc
|
cCSAus 244665 (process control equipment for hazardous locations, Class I, Division 2, Groups ABCD, T5)
|
- DNV
|
Temperature: B(0 - 55 °C); Humidity: B(up to 100%); Vibration: B(4 g); EMC: B(bridge and open deck)
|
- CCS
|
Yes
|
- LR
|
ENV1
|
- KR
|
Yes
|
- ABS
|
Yes
|
- BV
|
EC33B, Temperature: 5 - 55 °C, Vibration: 4 g, EMC: Bridge and open deck
|
- KC
|
Yes
|
MOQ: | 1 |
Price: | 120$/piece |
Standard Packaging: | 160*110*60mm |
Delivery Period: | 3 day |
Payment Method: | T/T |
Supply Capacity: | 1piece in stock |
Product Identification and Basics
The X20DO9322, distinguished by its material number, is a digital output module by B&R. It serves as a key component in industrial control systems. With 12 digital outputs, it provides a significant capacity for driving various external devices. This module is designed to be an integral part of systems where digital signals need to be converted into physical actions, making it suitable for a wide range of industrial applications.
Technical Features
One of the main features of the X20DO9322 is its source connection design. The outputs are configured for a source circuit, which determines the direction of current flow. This design choice offers flexibility in circuit design and compatibility with different types of loads. It also features 1 - wire connections, simplifying the wiring process and reducing the complexity of installations. Additionally, the module comes with integrated output protection. This protection mechanism safeguards the module and connected devices from potential electrical faults such as short - circuits and over - currents.
Application - Oriented Advantages
In industrial settings, the X20DO9322 proves highly beneficial. Its 12 - output configuration allows for the control of multiple devices simultaneously, such as solenoid valves, relays, or indicator lights. The source connection design enables efficient power distribution to the connected loads. The integrated output protection enhances the reliability of the system, reducing the risk of equipment damage due to electrical malfunctions. The simplicity of the 1 - wire connections makes installation and maintenance easier, ultimately improving the overall efficiency of industrial operations.
Category
|
Details
|
General Information
|
|
- Material Number
|
X20DO9322
|
- Brand
|
B&R
|
- Product Type
|
Digital Output Module
|
- Function
|
Convert digital signals from control systems to drive external devices in industrial applications
|
- B&R ID Code
|
0x1B9A
|
- Warranty
|
Usually 12 months (varies by region and distributor)
|
Output Specifications
|
|
- Number of Outputs
|
12
|
- Output Signal Type
|
Digital
|
- Nominal Voltage
|
24 VDC
|
- Switching Voltage
|
24 VDC (-15% / +20%)
|
- Nominal Output Current
|
0.5 A
|
- Total Nominal Current
|
6 A
|
- Connection Type
|
1 - wire connections
|
- Output Circuit
|
Source
|
- Output Protection
|
Thermal shutdown in case of overcurrent or short - circuit; internal freewheeling diode for switching inductive loads
|
- Diagnostic Status
|
Output monitoring with 10 ms delay
|
- Leakage Current (Output Off)
|
5 µA
|
- Rds(on)
|
210 mΩ
|
- Peak Short - Circuit Current
|
< 12 A
|
- Overload/Short - Circuit Recovery Time
|
Approx. 10 ms (depends on module temperature)
|
- Switching Delay (0 → 1)
|
< 300 µs
|
- Switching Delay (1 → 0)
|
< 300 µs
|
- Switching Frequency (Resistive Load)
|
Max. 500 Hz
|
- Braking Voltage (Inductive Load)
|
Typ. 50 VDC
|
- Insulation Voltage (Channel - Bus)
|
500 Veff
|
Power Requirements
|
|
- Bus Power Consumption
|
0.26 W
|
- Internal I/O Power Consumption
|
1.15 W
|
- Additional Power Dissipation by Actuators (Resistive)
|
+0.63 W
|
Electrical Isolation
|
|
- Channel - Bus Isolation
|
Yes
|
- Channel - Channel Isolation
|
No
|
- Channel - I/O Power Supply Isolation
|
No
|
Status and Diagnostics
|
|
- Status Indicators
|
I/O function per channel, operating state, module status
|
- Diagnostics
|
Module run/error and output diagnostics available via LED status indicators and software
|
Environmental Conditions
|
|
- Operating Temperature (Horizontal Mounting)
|
- 25 °C to 60 °C
|
- Operating Temperature (Vertical Mounting)
|
- 25 °C to 50 °C
|
- Storage Temperature
|
- 40 °C to 85 °C
|
- Transportation Temperature
|
- 40 °C to 85 °C
|
- Relative Humidity (Operation)
|
5% - 95%, non - condensing
|
- Relative Humidity (Storage)
|
5% - 95%, non - condensing
|
- Relative Humidity (Transportation)
|
5% - 95%, non - condensing
|
- Mounting Orientation
|
Horizontal and vertical
|
- Installation Elevation
|
0 - 2000 m: no limitation; > 2000 m: ambient temperature reduction of 0.5 °C per 100 m
|
- Protection Class
|
IP20
|
Mechanical Properties
|
|
- Mounting Method
|
Likely plug - in mounting (details may refer to product manual)
|
- Dimensions (W x H x D)
|
Approximately 2.2 cm x 12.4 cm x 12.6 cm
|
- Weight
|
Approximately 0.1 kg
|
- Pitch
|
12.5 + 0.2 mm
|
- Mandatory Accessories
|
Bus modules (e.g., X20BM11, X20BM15); Terminal blocks (e.g., X20TB12)
|
Certifications
|
|
- CE
|
Yes
|
- UKCA
|
Yes
|
- ATEX
|
Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
|
- UL
|
cULus E115267 (industrial control equipment)
|
- HazLoc
|
cCSAus 244665 (process control equipment for hazardous locations, Class I, Division 2, Groups ABCD, T5)
|
- DNV
|
Temperature: B(0 - 55 °C); Humidity: B(up to 100%); Vibration: B(4 g); EMC: B(bridge and open deck)
|
- CCS
|
Yes
|
- LR
|
ENV1
|
- KR
|
Yes
|
- ABS
|
Yes
|
- BV
|
EC33B, Temperature: 5 - 55 °C, Vibration: 4 g, EMC: Bridge and open deck
|
- KC
|